5.3. Isolation Measurement
5.3.1. Function menus of the isolation measurement
Main Display
Menu Display
F1 Button
Pop-up and shutdown RCD menu
F2 Button
Pop-up and shutdown RCD menu
F3 Button
Pop-up and shutdown RCD menu
F4 Button
None
Up Button
Up menu to select the current active sub-options.
Down Button
Down menu to select the current active sub-options.
Enter Button
Confirm the user select mode.
Insulation Resistance Display/Switch and Terminal Settings
Measurements should only be performed on de-energized circuits.