EasyManua.ls Logo

Pentair Fleck 5800 XTR - Replacing the Piston And;Or the Brine Valve

Pentair Fleck 5800 XTR
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 5800 - XTR - Maintenance
100 / 122 Ref. MKT-IM-006 / B - 16.01.2018
9.2.5. Replacing the piston and/or the brine valve
No. Operation
A Remove the gearing system, see “Power head disassembly/replacement”, page 98.
B Remove the screws (1).
C
Remove the piston and the top plate (2) by pulling the top plate on the points indicated by
arrows.
D Remove the o-ring (4).
E Remove the brine valve (5).
F Change the piston (3) and/or the brine valve (5).
G Lubricate the o-ring (4) with approved silicone grease.
H Reverse above procedure steps to rebuild.