Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 85 / 122
Connect a remote switch (such as a differential pressure switch) to the remote start input terminals
on the back of the XTR controller board. See 5.8. Electrical connections, page 45. When the remote
switch remains closed for the number of seconds specified in the remote regeneration screen, a
regeneration will be triggered regardless of volume, capacity, or time remaining until the next
scheduled regeneration.
Press to save and to return to the master settings screen or press to return to the master
settings screen without saving.
6.4.9. Chlorine generation screen
From the secondary master settings screen press the cl generation/low salt button to display the
chlorine generation screen.
Note
Cl generation/low salt will not be available for filter metered, immediate or delayed
regeneration type.
Mandatory
On the valves of series 5800, cl generation/low salt must be set OFF because the chlorine
cell kit managed by the XTR is not available for those valves.
cl generation/low salt: Contains settings for the chlorine generation. Select between OFF, low salt
detect. and ON.
regen. interval: Contains the setting for the chlorine generation interval. Set up from 1 to 255 to
define the interval of regeneration between each chlorination activation, e.g. 1 so that it is enabled at
every regeneration or 10 so that it is activated every 10 regenerations for instance.
Press to save and to return to the master settings screen or press to return to the master
settings screen without saving.
Chlorine Gen./Low Salt
cl generation/
low salt
on
regen. interval
1