24 / 122 Ref. MKT-IM-006 / B - 16.01.2018
3.5. Configurations for downflow softener, upflow softener and filter
3.5.1. Downflow
The valve is mounted with the DF piston kit, part number BR61837.
The injector is in the upper hole and the plug in the lower hole.
3.5.2. Upflow
The valve is mounted with the UF piston kit, part number BR61838.
The injector is in the lower hole and the plug in the upper hole.
Note
For upflow configuration, the injector cap is fitted with a pressure regulator.
3.5.3. Filter
A plug is placed in both holes.