Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 83 / 122
volume: Volume to be treated to turn the relay ON.
duration: Duration the relay will stay ON. Can be set for up to two hours.
Press to save and to pass to the second relay settings screen if present, or press to return to
the master settings screen without saving.
If already in second relay, or if second relay has not been activated, press to save and to return to
the master settings screen or press to return to the master settings screen without saving.
6.4.6. Meter screen
From the master settings screen press the meter button to display the meter screen.
Note
Not available with the timeclock regeneration type.
meter type: Contains settings for the type of meter installed with the system.
generic: If meter type is set to generic, permit to set up the number of pulses per liter.
continuous flow detect: When active, triggers an alarm when continuous flow of 0.5 gpm or 1 Lpm is
detected by the flow meter over a 24 hours period.
Press to save and to return to the master settings screen or press to return to the master
settings screen without saving.
Meter
generic
continuous
flow detect
10
pulses/L
off
meter type
generic