Installer Manual Fleck 5800 - XTR - System sizing
26 / 122 Ref. MKT-IM-006 / B - 16.01.2018
4. System sizing
4.1. Recommendations
4.1.1. Injector/DLFC/BLFC-Valve configuration
Note
In upflow configuration, the injector cap is fitted with a pressure regulator set to 1.4 or 2 bar.
4.2. Sizing a softener (single unit)
4.2.1. Parameters to be considered
Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
Valve
type
Diameter
Resin
volume
Injector DLFC BLFC
[in] L DF Color UF Color [gpm] DF [gpm] UF [gpm]
5800/
1650
4 4
0 Red
0000 Black 0.8
0.125
0.125
6 5 - 7
000 Brown 1.2
7 8 - 14
8 9 - 21
1 White
00 Violet
1.5
0.259 22 - 28 2
10 29 - 42 0 Red 2.4
0.2512 43 - 56
2 Blue 1 White
3.5
0.50
13 57 - 70 4
14 71- 85
3 Yellow 2 Blue
5
0.50
16 86 - 113 7