Installer Manual Fleck 5800 - XTR - Troubleshooting
Ref. MKT-IM-006 / B - 16.01.2018 107 / 122
10.1. Error detection
If an error in valve or controller function occurs, an alarm will sound and the home screen will display
the error alert button and the alarm button .
Press the alarm button to mute the alarm.
Press the error alert button to view information about the error.
If the display is in sleep mode when an error occurs, the screen will turn on for five minutes. The error
will beep for one second per minute until the error is cleared. If the error is not cleared after five
minutes, the screen will switch to power saving mode and display the error alert button as a screen
saver.
10.2. Error alerts
Note
An error alert appears on the home screen if an error condition is detected. Press the error
alert button to view the error message.
Note
Most error alerts are cleared at regeneration. If the error persists following a regeneration
attempt the appropriate reset and recovery procedure below or contact technical support.
Error screen
display
Cause Reset and recovery
Optical Sensor
Undesired change
detected in the
optical sensor
An undesired optical
sensor state change
occurred.
Non-critical error. Extra optical sensor pulse detected.
Press the Regeneration button to advance motor to
clear error.
Water treatment
wed
12:01 am
2 d
treatment
tank refill
rapid rinse
backwash
draw

Table of Contents