Installer Manual Fleck 5800 - XTR - Programming
Ref. MKT-IM-006 / B - 16.01.2018 51 / 122
5. Vacation → Halts all scheduled regenerations when pressed; press
again to resume normal operation.
6. Regeneration
cycle wheel
→ Displays the cycle steps the valve will step through during
service and regeneration; the current cycle step is always
shown on green.
Note
On metered units, the "Treatment" step on the regeneration cycle wheel will flash when
water is flowing through the unit.
7. Rapid Rinse → Water flows from the top of the vessel to the bottom of the
vessel to rinse the media.
8. Tank Refill → Brine tank is refilled with water.
9. Treatment → The unit is treating water.
10. Day and time → Displays the currently programmed day of the week and
time. This button will flash at the start-up and if the
supercapacitor is discharged
11. Next scheduled
regeneration
→ Displays the time to next scheduled regeneration, or volume
remaining until regeneration in meter systems.
12. Backwash → Water flows from the bottom of the vessel to the top of the
vessel to clean and mix the media.
13. Draw → Brine is drawn into the media and then slowly rinsed out.
14. Pause → Valve comes back in service position to allow brine
preparation after refill. Shown if variable refill/brining
regeneration flow has been selected in master setting.
15. Custom → Shown if custom regeneration flow has been selected in
master setting.
16. Home → Displays the home screen.