EasyManuals Logo

Pentair Sta-rite INTELLIPRO User Manual

Pentair Sta-rite INTELLIPRO
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
INTELLIPRO
®
Variable Speed Pump Installation and User’s Guide
20
INTELLIPRO
®
Variable Speed Pump Installation and User’s Guide
MAINTENANCE
Cleaning the Pump Strainer Basket
1. Press Start/Stop button on the pump and turn
off the pump at the circuit breaker. Disconnect
communication cable from pump.
2. Relievepressureinthesystem.
3. Turnthelidandclampcounter-clockwiseandremove
from the pump.
4. Removedebris and rinseoutthebasket.Replace
thebasketifitiscracked.
5. Putthebasketbackintothehousing. Be sure to align
thenotchinthebottomofthebasketwiththeribin
the bottom of the volute.
6. Fillthepumppotandvoluteuptotheinletportwith
water.
7. Cleanthelidandclamp,O-ring,andsealingsurface
of the pump pot.
Note:ItisimportanttokeepthelidO-ringcleanand
well lubricated.
8. Reinstallthelidbyplacingtheclampandlidonthe
pot.BesurethelidO-ringisproperlyplaced.
Seattheclampandlidonthepumpthenturnclockwise
untilthelockingringhandlesarehorizontal.
9. Turnthepower“ON”atthecircuitbreaker.Reconnect
communication cable from pump.
10. Openthemanualairreliefvalveonthetopofthe
filter. Stand clear of the filter.
11. Waituntilallpressureisrelieved.Startthepump.
12. Bleedairfromthelteruntilasteadystreamof
water comes out of the filter air relief valve. Close
the manual air relief valve.
Pump Strainer Basket
Thestrainerbasket(or‘strainerpot’),islocatedinfrontof
thepumphousing.Thestrainerbasketmustbekeptclean
andfreeofdebris.Inspectbasketthroughthelidonthe
top of the housing. Be sure to visually inspect the strainer
basketatleastonceaweek.Dirtystrainerbasketsreduce
filter and heater efficiency and put abnormal stress on
the pump motor.
DO NOT open the strainer pot if the IntelliPro
®
Variable Speed Pump fails to prime or if pump has been operating without water in
the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding
hot water. Opening the pump may cause serious personal injury. In order to avoid the possibility of personal injury, make sure the
suction and discharge valves are open and strainer pot temperature is cool to touch, then open with extreme caution.
To prevent damage to the pump and for proper operation of the system, clean pump strainer and skimmer baskets regularly.
Winterizing
To protect the pump electronics from freeze damage,
the pump will switch on to generate internal heat as the
temperature drops below freezing. TheAntiFreeze
feature on the pump is not intended to protect the
system plumbing from freezing.
• In mild climate areas, when temporary freezing
conditions may occur, run your filtering equipment
all night to prevent freezing.
• You are responsible for determining when freezing
conditions may occur. If freezing conditions are
expected,takethefollowingstepstoreducetherisk
of freeze damage. Freeze damage is not covered
under warranty.
To prevent freeze damage, follow the procedures below:
1. Shutoffelectricalpowerforthepumpatthecircuit
breaker.
2. Drainthewateroutofthepumphousingbyremoving
the two thumb-twist drain plugs from the housing.
Storetheplugsinthepumpbasket.
3. Coverthemotortoprotectitfromsevererain,snow
and ice.
Note: Donotwrapmotorwithplasticorotherairtight
materials during winter storage. The motor may be
covered during a storm, winter storage, etc., but never
when operating or expecting operation.
THIS SYSTEM OPERATES UNDER HIGH PRESSURE.
When any part of the circulating system (e.g., Lock Ring,
Pump, Filter, Valves, etc.) is serviced, air can enter the
system and become pressurized. Pressurized air can
cause the lid to separate which can result in serious
injury, death, or property damage.
To avoid this potential hazard, follow above instructions.
Clamp, pot
O-Ring
Lid
StrainerBasket
Drain
Plugs
Volute
StrainerPotAssembly

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair Sta-rite INTELLIPRO and is the answer not in the manual?

Pentair Sta-rite INTELLIPRO Specifications

General IconGeneral
BrandPentair
ModelSta-rite INTELLIPRO
CategoryWater Pump
LanguageEnglish

Related product manuals