CONNECTING TO AN AUTOMATION SYSTEM
External Control with IntelliComm
®
Communication Center
Use the RS-485 communications cable to remotely
control the pump from an IntelliComm communication
center.TheIntelliCommsystemprovidesfour(4)pairs
of input terminal connections. These inputs are actuated
byeither15-240VACor15-100VDC.Usethedevice
inputs, to control the programmed pump speeds.
Note:FortheIntelliPro
®
Variable Speed Pump to accept
commands from the IntelliComm system, the pump
mustbeinthe“RunningSchedules”mode(LEDabove
Start/Stopbuttonison).Ifmorethanoneinputisactive,
the highest number will be communicated to the pump.
The IntelliComm system will always communicate to
pumpusingADDRESS#1.
Refer back to page 12 for instructions for setting up
Programs in the External Control menu.
External Control is for programming speeds that will
run when the IntelliComm communication center
controller sends it a command.
Forexample,Terminal3and4inIntelliCommsystem
willcorrespondtoExternalControlProgram#1.(5
and6toExtCtrl#2).UsetheExternalControlfeature
to program the IntelliComm communication center.
Terminal
Number
Terminal
Name
Voltage
Max.
Current
Phase
Type
Frequency
1-2
Power
Supply
100-240
VAC
100mA 1Input 50/60Hz
3-4
Program
1
15-240
VAC
or
15-100
VDC
1mA 1Input
50/60Hz
5-6
Program
2
15-240
VAC
or
15-100
VDC
1mA 1Input 50/60Hz
7-8 Program
3
15-240
VAC
or
15-100
VDC
1mA
1Input 50/60Hz
9-10
Program
4
15-240
VAC
or
15-100
VDC
1mA 1Input
50/60Hz
11
12
RS-485
+Data:
Yellow
-Data:
Green
-5to+5
VDC
5mA
1
Output N/A
Ground
IntelliComm Communication Center
Program Number Priority
Ifprograms1 and 2 are activated,program2 will
run,regardlessoftheassignedspeed(RPM).The
higherprogramnumberwillalwaystakepriority.
Connecting to EasyTouch
®
and
IntelliTouch
®
Control Systems
The pump can be controlled by an EasyTouch or
IntelliTouchsystemviatheRS-485communication
cable.TheEasyTouchand/orIntelliTouchcontrol
system starts, stops and controls the speed of the pump.
EasyTouch and/or IntelliTouch systems rewrite the
pumpmemorywhenacommandisgiven.Thiscantake
several seconds and can cause a delay until the pump
physically responds.
The pump control panel is disabled when communicating
with an EasyTouch and/or IntelliTouch system. The
EasyTouch and/or IntelliTouch system will not start
communicating with the pump until the pump is
assigned to a circuit. Thedefaultpumpaddressis“1”
(onlyaddressforEasyTouchsystem).
Wiring Terminal Descriptions for IntelliComm
Communication Center
See page 8 for details about how to check and or set
the pump address. For more information, refer to the
IntelliTouch (P/N 520100) or EasyTouch Automation
System User’s Guide (P/N 520584).