55
29.[Adjustment]SR adjustment 2 (Gain adjustment)
*It is the same adjustment with K100D except adjusting software and power source.
[Caution-1] Execute this adjustment when replaced T100, T970 and C100 block.
[Caution-2] [SR adjustment- 1] should be completed before this adjustment.
[Caution-3] Do not give the camera the vibration when you adjust it.
Put on the sturdy and stabile table.
[Caution-4] The weight of the stage is more than 10kg, so pay attention the handling
[Required equipments] Adjustment software for 76830 (SR gain adjustment), USB cable, AC adaptor,
Personal computer (Windows 2000 or XP which equipped USB port), DA50-200mm lens
SR gain adjustment set (Controller, stage, speed meter), Chart (Attached in service manual)
29-1. Setting the computer
① Copy [SR Gain adjustment] folder into the computer.
② [VB runtime set-up] should be completed.
*Method for adjustment is the same as K100D. (Refer to service manual for 76700)
*If adjustment is NG, refer to Technical information [Table of Error code]