Input
61
Group
Parameter
Description
User level
Setting range
Set value
7
730 Lift delay for the presser foot after seam end
[ms]
B,C 0 - 2000 50
734 Timing of output A2 (thread trimming) B,C 10 - 60 40
760 Stitch count for remaining thread after acti-
vating the bobbin thread monitor during di-
rect bobbin thread monitoring (via sensor)
1
= Multiplier for the fixed value x10 during
direct monitoring
2 = Multiplier for the fixed value x200 during
indirect monitoring
A,B,C 0 - 250 5
761 Extend thread tension release / thread ten-
sioning
B,C 0 - 80 0
770 Lift delay for the presser foot in pedal posi-
tion "-1"
C 10 - 250 80
789 Needle position "10" (location finding posi-
tion)
B,C 0 - 255 239
797 Hardware test
ON = yes
OFF = no
C 0 - 1 0
798 User level "C"
0 = operator level "a"
1 = mechanic level "b"
11 = service level "c"
A, B,C 0 - 20 0
799 Selected machine class C 1 - 1 1
8
800 Direction of rotation of motor as viewed look-
ing at the V-belt pulley
1 = anti-clockwise rotation
0 = clockwise rotation
C 0 - 1 0
801 Reverse turning angle after seam end B,C 10 - 212 16
880 Max. starting current [A] C 1 - 30 10
884 Proportional amplification of the speed con-
trol (general)
B,C 1 - 24 10
885 Integral amplification of the speed control C 10 - 80 50
886 Proportional amplification of the position con-
troller
C 1 - 15 8