Input
62
Group
Parameter
Description
User level
Setting range
Set value
8
887 Differential amplification of the position
controller
C 1 - 15 8
889 Time for position control
0 = always
C 0 - 2500 400
890 Proportional amplification of the higher
ranking position controller for standstill brake
C 1 - 25 15
897 MINI motor variant
1 = long
0 = short
C 0 - 1 0
898 Motor current limit
ON = 15A
OFF = 10A
C ON - OFF OFF
9
900
Additional proportional amplification of the
speed control
B,C 1 - 24 12
901 Trimming release speed B,C 30 - 500 300
933 Change the display
ON = diagnosis
OFF = normal display
C ON - OFF OFF
10
1001 Starting angle of stepper B,C 0 - 255 110
1003 Feed roller radius C 5 - 50 11