Care and maintenance
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
10.04 Checking the air pressure
Check the air pressure on the gauge 1
before every use of the machine.
The gauge 1 must show a pressure of
approx. 6 bar.
Adjust to this value if necessary.
To do so lift button 2 and turn it until the
gauge shows approx. 6 bar.
10.05 Emptying/cleaning the water container of the air filter/regulator
Turn the machine off!
Disconnect the compressed air
hose from the air filter/
regulator.
Emptying water container 1
Water container 1 empties itself
automatically when the compressed air
hose is removed from the air filter/
regulator.
Unscrew water container 1.
Screw out filter 2.
Clean filter 2 with compressed air or
isopropyl alcohol
(Part No. 95-665 735-91)
Screw filter 2 back in and screw on
water trap 1.
Fig. 10 - 05
2
1
10
12
0
6
4
2
8
16
14
100
50
150
0
200
230
A
Fig. 10 - 06
2
1
10 - 4