Mixing Pump PFT G4
Operation
2007-09-05 45
Pos: 6.19 /KN2006-Pr ojekte/Knauf/Bedien ung/Mischpumpe PFT G4/1. 1 Reinigen_Titel @ 36\ mod_1177341260047_29 3361.doc @ 445924
6.6 Cleaning
Pos: 6.20 /KN2006-Pr ojekte/Knauf/Bedien ung/Mischpumpe PFT G4/1. 1 Reinigen_ANSI @ 37\ mod_1177405397896_2933 61.doc @ 447266
NOTICE
Damage due to improper cleaning after operation!
Always clean the machine on a daily basis after your work is
completed. Mortar deposits and remnants otherwise plug up
and block the machine's pipes, hoses and valves, which will
adversely affect the machine's functioning.
Protect your investment!
The machine must be cleaned daily after work is completed:
1. Switch off the machine.
Check mortar pressure
Fig. 39: Mortar pressure at 0
2. On the mortar pressure manometer (Fig. 39/1) always check
whether mortar pressure has dropped to 0.
DANGER! Excess pressure on the machine.
When opening machine components these components can
unexpectedly fly open and seriously injure the operator or
others. Only open the machine if the pressure has dropped to
0.
Cleaning the mixing pipe
Fig. 40: Open the motor tilt flange
3. Open the quick lock (Fig. 40/1) on the motor tilt flange and tilt
the motor.
4. Remove the mixing helix (
Fig. 40/2) and clean it.