Mixing Pump PFT G4
Operation
52 2007-09-05
Pos: 6.25 /KN2006-SM/Be dienung/007 1.1 Sti llsetzen im Notfall_ Titel @ 9\mod_114440504745 6_293361.doc @ 293693
6.8 Shutdown in emergency situations
Pos: 6.26 /KN2006-Pr ojekte/Knauf/Bedien ung/Mischpumpe PFT G4/1. 1 Stillsetzen im Notfa ll, Anlage_ANSI @ 37\mo d_1177407045808_2 93361.doc @ 447434
In case of an emergency, machine movements must be stopped
immediately and the energy supply must be switched off.
Shutdown in emergency situations
Fig. 57: Main switch
In case of an emergency, proceed as follows:
1. Immediately switch off the main switch (Fig. 57) which also
serves as EMERGENCY STOP.
2. Safeguard the main switch from being switched on again.
3. Inform the responsible parties at the implementation site.
4. Notify emergency services as needed.
5. Get persons out of the danger zone, initiate first-aid measures.
6. Keep entry ways clear for rescue vehicles.
After the rescue measures
7. Depending on the seriousness of the emergency situation,
inform the responsible government agencies.
8. Assign specialized personnel to resolve the malfunction.
WARNING! Life-threatening danger if machine is restarted
without authorization. Prior to restarting the machine ensure
that no one is in the danger zone.
9. Prior to starting up the machine again check and ensure that all
safety devices are installed and functioning.