FL SWITCH 2000 / FL NAT 2000
104 / 226
PHOENIX CONTACT 108997_en_04
Interface: Ethernet (RJ45)
Number of interfaces 4
Connection method RJ45
Note on the connection method Auto negotiation and autocrossing
Transmission physics Copper
Transmission speed 10/100 Mbps
Transmission length 100 m (per segment)
Interface: SFP module
Number of interfaces 2
Connection method SFP ports
Transmission physics Depending on the SFP module
Transmission speed 100 Mbps (full duplex)
Transmission length up to 40 km (Depending on the fiber/SFP module used)
Interface: Ethernet (combo)
Number of interfaces 2
Connection method SFP or RJ45 ports
Note on the connection method Auto negotiation and autocrossing
Transmission physics Depending on the SFP module
Transmission speed 10/100 Mbps (full duplex)
Transmission length up to 40 km (Depending on the fiber/SFP module used)
Supply voltage
Supply voltage 24 VDC (redundant)
Residual ripple 3.6 V
PP
(within the permitted voltage range)
Supply voltage range 12 VDC ... 57 VDC
Typical current consumption 250 mA (at U
S
= 24VDC and 25°C ambient temperature)
Max. current consumption 1.4 A (U
S
= Min, T
amb
= Max, DO
I
= Max)
Maximum power dissipation for nominal condition 7.8 W (U
S
= Min, T
amb
= Max, DO
I
= Max)
Test section for one minute 500 VDC
Mechanical tests
Mechanical tests Free fall in accordance with EN61131-2
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Vibration (storage/transport) 5g, 150 Hz, in acc. with IEC 60068-2-6
Shock (operation) 30g (EN60068-2-27)
Conformity with EMC directives
Electromagnetic compatibility Conformance with EMC Directive 2014/30/EU
Conducted noise emission EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A
Interference emission EN 61000-6-2 EN 61000-6-4 (interference) Class A
Immunity to burst EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A

Table of Contents

Other manuals for Phoenix Contact FL SWITCH 2005

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Phoenix Contact FL SWITCH 2005 and is the answer not in the manual?

Phoenix Contact FL SWITCH 2005 Specifications

General IconGeneral
BrandPhoenix Contact
ModelFL SWITCH 2005
CategorySwitch
LanguageEnglish

Related product manuals