Wooden nishes, e.g. Wood mantels, may be mounted on the surround.
Wood mantels MUST be:
- installed outside the heat radiation area;
- self-supporting;
- installed with 1cm air gap from the surround or from the heating part.
a The expansion joint is in ceramic bre, which has the function
of insulating the surround from the metal structure of the
stove.
DT2010178-00
1.14 wOOd MANTEL PROTECTION
1 cm
Load-bearing
Firebox
1 cm
Expansion joint
Hood or surround
Surround
Ornamental
ledge
Fig. 23
Make sure there is a power socket 230V 50Hz in the rear stove wall ready for installing the ventilation kit and a switch on the outside of the cladding
to be able to cut off the power supply during maintenance or when the appliance is not being used.
The installation must be earthed and tted with a circuit breaker in accordance with current wiring regulations.
a When connected ensure that the power cable does not come into contact with hot parts.
The product must be installed and used in compliance with the manufacturer’s instructions and European and national standards as well as local
regulations.
a When a ue pipe passes through a wall or a ceiling, special installation methods must be applied (protection, thermal insulation,
distances from heat-sensitive materials, etc.). See the paragraph “CONNECTING TO A CONVENTIONAL CHIMNEY”.
It is also recommended that all elements made of combustible or inammable material, such as beams, wooden furniture, curtaining, ammable
liquids, etc. be kept outside the heat radiation range of the stove and at a distance of at least 1m from the heating block.
For other information, see the paragraph “MINIMUM SAFETY DISTANCES and “CONNECTING TO A CONVENTIONAL CHIMNEY”.
The ue pipe, chimney stack, chimney and fresh air intake must always be free of obstructions, clean and checked periodically, that is, at least
twice during the seasonal period from the lighting of the stove and during its use. When the stove has not been used for some time it is advisable
to carry out the checks mentioned above. For further information, consult a chimneysweep.
Only use recommended fuels (See section FUEL”).
DT2010179-01
1.15 ELECTRIC POwER SUPPLy
DT2010027-02
1.16 PREvENTION OF dOMESTIC FIRES
H072047UK0 / DT2001513 – 04
13
English
DT2030272-00