SMOKE BOX DEPRESSION
Description Display message
The pressure switch, which is connected to the smoke ue, controls the vacuum inside the ue
allowing for the appliance to be used in total safety.
The pressure switch activates and switches off the appliance if there is a change in the correct
operating conditions (as a result of bad installation, obstacles or impediments in the ue, negligent
maintenance, adverse weather conditions such as persistent wind etc..).
The door open sensor veries that the door to the appliance has been correctly closed.
If one or both of the aforementioned safety devices activate, electrical power to the auger is interrupted
thus stopping pellet feed to the brazier followed by the activation of the appliance shut down process.
- The display shows the message E1 and the time or temperature in relation to initial settings.
- The alarm beep sounds.
E1
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the key to deactivate the appliance.
- The beep stops.
- Wait and make sure that the combustion of the pellets in the brazier is complete and that the smoke
motor is off.
- After having cleaned the brazier, close the door and start the appliance by pressing the ON/OFF key
(the message E1 must not appear on the display, if this occurs call the Technical Assistance Centre).
Proper pressure switch operation is check when the stove is started so that the appliance can be
used in utmost safety.
- If there is a fault on the pressure switch, he display shows the message E2 and the time or
temperature in relation to initial settings.
- The alarm beep sounds.
E2
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the key to deactivate the appliance.
- The beep stops.
- Call the Technical Assistance Centre. DT2012624-00
DT2010223-01
6.20 SAFETy dEvICES
a Some parts of the stove (door, handle, ceramic parts) may reach extremely high temperatures during operation.
Remember to maintain the safety distances indicated previously.
Be extremely careful, take the necessary precautions and always follow the instructions.
If any part of the appliance or of the outow pipe leaks smoke while the stove is in use, shut down the appliance immediately and air out the room(s).
Once cooled try to look for the cause of the leak and call specialised technicians if necessary.
The unit is equipped with some devices which intervene in order to ensure the safe operation.
a The safety devices are designed to eliminate any risk of damage to persons, animals or things, and their tampering or intervention by
unauthorized personnel could compromise security.
Finally, if SOLUTION 3 and SOLUTION 4 are selected, even more thrust will be required and in this case fan speed “03”or “04”should be selected
on the control panel.
To select the desired Multifuoco value, see the paragraph “START-UP AND STANDARD OPERATION”.
H072047UK0 / DT2001513 – 04
51