PELLET HOPPER TEMPERATURE
Description Display message
The automatic rearm thermal probe is positioned on the pellet hopper and serves to safeguard it
against excessive thermal excursions.
If the temperature of the pellet hopper exceeds the safety threshold, the thermostat isolates the
supply voltage to the auger, thus stopping pellet feed to the brazier, followed by engaged appliance
shut down.
- The display shows the message E3 and the time or temperature in relation to initial settings.
- The alarm beep sounds.
E3
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the key to deactivate the appliance.
- The beep stops.
- Wait and make sure that the combustion of the pellets in the brazier is complete and that the smoke
motor is off.
- Clean the brazier, start the appliance by pressing the ON/OFF key (the message "E3" must not
appear on the display, if this occurs call the Technical Assistance Centre).
DT2012625-00
SMOKE TEMPERATURE PROBE
Description Display message
The smoke probe is connected to the electronic board and constantly measures operating temperature,
allowing the appliance to be used in total safety.
If the temperature exceeds the safety threshold, the board isolates the supply voltage to the auger,
thus stopping pellet feed to the brazier, followed by engaged appliance shut down.
- The display shows the message E4 and the time or temperature in relation to initial settings.
- The alarm beep sounds.
E4
!
1
12:0022
.
c
The alarm is triggered if the smoke probe connector momentarily and/or accidentally detaches from
its seat or if the connector is not positioned properly on the electronic board.
- The display shows the message E8 and the time or temperature in relation to initial settings.
- The alarm beep sounds.
E8
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the key to deactivate the appliance.
- The beep stops.
- Call the Technical Assistance Centre.