STOVE ROOM TEMPERATURE PROBE
Description Display message
The room probe is connected to the rear of the stove and constantly monitors room temperature near
the appliance, allowing for its use in utmost safety.
The alarm is triggered if the smoke probe connector momentarily and/or accidentally detaches from
its seat.
- The display shows the message of the power set (for example P4), 00 (if in “DISPLAY MODE” the
temperature was set) and the message E10.
- The message ROOM PROBE is stored in “MENU PARAMETERS” under the item “MEMORY
COUNTER” .
The setback does not shut down the stove that continues to function normally according to power
level set.
However, the room temperature set by the user is not taken into account.
E10
P4
!
1
12:0022
.
c
WHAT TO DO
- Ret the probe into its seat (see the section “ELECTRICAL CONNECTIONS AND CONTROL
DEVICES”).
- The display enables the room temperature and it will be once again shown on screen.
DT2012627-00
AUGER SAFETY
Description Display message
- The message E6 is shown on the display.
This means that during operation an anomaly has been detected on the auger with continuous pellet
feed.
- The alarm beep sounds.
E6
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the ON/OFF key to deactivate the appliance.
- The beep stops.
- Call the Technical Assistance Centre.
UNPROGRAMMED STOP
Description Display message
- The message E7 is shown on the display.
This means that smoke temperature falls below the minimum operating temperature when the stove
is operating.
- The alarm beep sounds.
E7
!
1
12:0022
.
c
WHAT TO DO
- Press and briey hold the ON/OFF key to deactivate the appliance.
- The beep stops.
- Check the pellet load in the hopper and ll it if necessary.
- Make sure that the brazier is not obstructed with pellets of combustion residuals.
- If the problem persists please contact the Technical Assistance Centre.