FAN MODE
Function Action Display message
Select fan mode
menu
Press the MENU key, with the SELECT MENU key select MODE FANS and
conrm by pressing the SET key.
1
1
1
MODE
FANS
FANS
SEPARATE
FANS
NORMAL
Select normal fans or
separate fans
Press the SELECT MENU key and select FANS SEPARATE or FANS
NORMAL, conrm by pressing the SET key. After conrmation using the
SET key, the remote control automatically returns to the initial display.
1
1
1
MODE
FANS
FANS
SEPARATE
FANS
NORMAL
1
1
1
MODE
FANS
FANS
SEPARATE
FANS
NORMAL
DT2040069-04
6.12 FAN MOdE
This function allows you to have the two fans operating at the same speed (NORMAL FANS) or at different speeds (SEPARATE FANS). To maximise
the potential of the Multifuoco fan functions, read the sections MULTIFUOCO SYSTEM e MULTICOMFORT OPERATION.
DT2010256-00
6.13 MULTICOMFORT
The pellet stove is tted with a Multicomfort function which works in conjunction with the Multifuoco System to improve heat distribution. This
function allows the room temperature to be read from the stove or from the remote control, so that the Multifuoco settings can be varied according
to the requirements of the rooms to be heated
If the airow from your stove has been ducted to other rooms you may read the temperature in the room where the stove is installed or in the room
where the remote control is positioned.
Example: your stove is installed in a small room and you are ducting the heat only from the rear of the stove (see solution 1 in the section
"MULTIFUOCO SYSTEM"). You can position the remote control in the room to which the hot air has been ducted and set the required temperature
from this room. To carry out the necessary settings see the Multicomfort menu.
The pellet stove is tted with another function which allows the installation to operate with separate fans. This function allows differentiated hot air
distribution from the two fans thereby fully exploiting the functionality of the Multicomfort system.
Example: your stove is installed in a room and hot air is ducted from one fan to an adjoining room (see solution 2 in the section "MULTIFUOCO
SYSTEM"). You can position the remote control in the room to which the hot air has been ducted and set the required temperature from this room.
You can also set the fans separately, increasing or decreasing the Multifuoco airow for the same room
To set the functions, see the Multicomfort - Fans mode menu.
For airow controls see the paragraph Normal operation.