8 Installation
Page 42
Installation manual PMCprimo Drive2
8.4.6 Notes on connection techniques
Shielding connection to the front panel:
Remove the outer covering of the
cable and the shielding braid from
the cores for the required length.
Secure the cores with a cable tie.
Remove the outer covering of the
cable over a length of about
30mm, without damaging the
shielding braid.
Pull a cable tie through the slot in
the shielding rail (front panel) of
the PMCprimo Drive2.
Use the cable tie to clamp the
shielding braid of the cable firmly
to the shielding rail.