EasyManuals Logo
Home>Polycom>Conference System>SoundStructure C16

Polycom SoundStructure C16 User Manual

Polycom SoundStructure C16
712 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #662 background imageLoading...
Page #662 background image
Design Guide for the Polycom SoundStructure C16, C12, C8, and SR12
A - 146
ir_chan_id
Set IR Remote Channel ID
Description
This parameter sets the channel ID that the specified IR input will respond to.
Polycom HDX IR remotes can be configured to use different channel IDs so
that multiple remotes can be used in the same room to control different equip-
ment without interfering with each other. By default, the HDX IR remote used
channel ID 3. This can be changed by following the instructions in the HDX
Administrator’s Guide.
ser_baud
RS-232 Baud Rate
Description
This parameter sets the baud rate for the RS-232 port. Hardware flow control
should be enabled for baud rates over 9600 bps (see the ser_flow parameter).
Argument Argument value
Channel Type Virtual Channel
Value Type Integer
Read/Write Mode Read/Write
Phys Chans Infrared Remote Input
Virt Chans Control
System Limits Minimum: 0, Maximum: 15
Default 3
User limits
Supported
No
Event Source No
Argument Argument value
Channel Type Device-Specific System
Value Type List
Read/Write Mode Read/Write
Values
9600 : 9600 bits per second (default)
19200 : 19200 bits per second
38400 : 38400 bits per second
57600 : 57600 bits per second
115200 : 115200 bits per second
Event Source No

Table of Contents

Other manuals for Polycom SoundStructure C16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom SoundStructure C16 and is the answer not in the manual?

Polycom SoundStructure C16 Specifications

General IconGeneral
BrandPolycom
ModelSoundStructure C16
CategoryConference System
LanguageEnglish

Related product manuals