S01PEQOT1,2,1
Query current type setting of 
parametric EQ on output B , band 
1. 
S01PEQOTB,1,t , where t is the current 
setting of the type parameter for the 
parametric EQ on output B , band 1. If the 
type parameter of this filter is set to the same 
value given in the example above, then the 
status message will be S01PEQOTB,1,1 . 
8.128. PHANTOM -- Enable Phantom Power on Input 1
This command sets or queries the status of phantom power on microphone input 1. 
This command is a channel boolean command. See 
Section 6.3 and Section 6.1 for more information 
on this type of command. 
This command is saved to non-volatile memory only as part of a preset. The state of this command 
will be restored after power-up only if a preset is saved and that preset is set to be the power-on 
preset. 
Example Description Status Message
S01PHANTOM11
Enable phantom power for input 
channel 1. 
S01PHANTOM11
S01PHANTOM10
Disable phantom power for input 
channel 1. 
S01PHANTOM10
S01PHANTOM12
Toggle phantom power state for 
input channel 1. 
S01PHANTOM1x , where x is 0 or 1 
depending on the current state of phantom 
power on input channel 1. 
S01PHANTOM1?
Query state of phantom power for 
input channel 1. 
S01PHANTOM1x , where x is 0 or 1 
depending on the current state of phantom 
power on input channel 1. 
8.129. PHONE -- Take Phone On-Hook or Off-Hook
This command sets or queries the on-hook status of the phone interface. 
This command is a boolean command. See 
Section 6.1 for more information on this type of command. 
Example Description Status Message
S01PHONE0
Put phone interface on-hook (hang up 
phone interface). 
S01PHONE0
S01PHONE1
Take phone interface off-hook (pick up 
phone interface). 
S01PHONE1