EasyManuals Logo

Polycom Vortex EF2211 User Manual

Polycom Vortex EF2211
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #40 background imageLoading...
Page #40 background image
S01AMREFE11
Enable automixer reference mode for
Automixer 1.
S01AMREFE11
S01AMREFE1?
Query current setting of automixer
reference mode for Automixer 1.
S01AMREFE1x , where x is 0 or 1
depending on the current setting of
automixer reference mode for Automixer 1.
8.30. BAUD -- Set Baud Rate for RS-232 Port
This command sets the baud rate for the rear panel RS-232 port. The baud rate is specified in bits per
second (bps). Valid baud rates are 9600, 19200, and 38400. Although, this command returns an
acknowledgement, it is likely that you will not receive it, since it is sent at the new baud rate. If you
setup your control system to quickly change its RS-232 baud rate after you send this command, then
you can probably receive the acknowledgement at the new baud rate.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
S01BAUD38400
Set baud rate of rear panel RS-232
port to 38400 bps.
S01BAUD38400
S01BAUD?
Query current baud rate of rear
panel RS-232 port.
S01BAUDx , where x is 9600, 19200, or
38400 depending on the current baud rate
setting.
8.31. BLAUTO -- Enable Automatic BLDATA Messages
This command sets whether or not BLDATA messages are automatically generated by the Vortex. See
the
BLDATA command for more information.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01BLAUTO0
Disable automatic
BLDATA messages.
S01BLAUTO0
S01BLAUTO1
Enable automatic
BLDATA messages.
S01BLAUTO1
S01BLAUTO2
Toggle enabled status of automatic
BLDATA messages.
S01BLAUTOx , where x is 0 or 1
depending on the current setting of
BLAUTO.

Table of Contents

Other manuals for Polycom Vortex EF2211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2211 and is the answer not in the manual?

Polycom Vortex EF2211 Specifications

Power IconPower
input voltage110-240 VAC
frequency47-63 Hz
power consumption25 W
phantom power24 V
Connectors IconConnectors
RS-232DB9F
EF Bus In/OutRJ45
Telephone Line/SetRJ11
Control/StatusDB25F
Audio3.5mm quick connect terminal blocks
Audio Specifications IconAudio Specifications
microphone input-30 dBu to +0 dBu
line inputs-20 dBu to +0 dBu
line outputs-20 dBu to +0 dBu
loudspeaker output10 W, 4-16 Ohms
input impedance10 k Ohms
output impedance50 Ohms
headroom20 dB
signal to noise ratio85 dB
frequency response20 Hz - 22 kHz
Echo and Noise Cancellation IconEcho and Noise Cancellation
total cancellation65 dB
convergence rate40 dB/second
noise cancellation0-15 dB
echo cancellation40 dB, total >65 dB
convergence30 dB/second
cancellation span32 ms
acoustic echo cancellation span270 ms
Operating Environment IconOperating Environment
operating temperature0 °C - 40 °C
status outputs5 V, 20 mA each
Weight and Dimensions IconWeight and Dimensions
width483 mm
length244 mm
height45 mm
weight1.8 kg
shipping weight2.5 kg

Related product manuals