S01MIC1?
Query enabled status of microphone gain
stage for input channel 1.
S01MIC1x , where x is 0 or 1 depending
on the current enabled state of the
microphone gain stage on input channel
1.
8.103. MINI -- Enable Modem Initialization String
This command controls whether or not the modem initialization string is sent at power-up. If MINI is
0, then the modem initialization string is not sent. If MINI is 1, then the modem initialization string is
sent. The text of the modem initialization string is set via the
MINISTR command.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.
Example Description Status Message
S01MINI1
Enable modem initialization string.
S01MINI1
S01MINI0
Disable modem initialization string.
S01MINI0
S01MINI2
Toggle enabled state of modem initialization
string.
S01MINIx , where x is 0 or 1 depending
on the current enabled state of the
modem initialization string.
S01MINI?
Query enabled state of modem initialization
string.
S01MINIx , where x is 0 or 1 depending
on the current enabled state of the
modem initialization string.
8.104. MINISTR -- Set Modem Initialization String
This command is used to set or query the modem initialization string. The string can be a maximum of
32 characters long. The recommended modem initialization string for the Vortex is:
ATF1E0&B1S0=2
This can be set via the following command.
S01MINISTRATF1E0&B1S0=2
Whether or not the modem initialization string is sent at power-up is controlled via the
MINI
command.
This command is saved to global non-volatile memory and is not part of a preset. Its value is saved
each time it is changed. It will retain its value after power-down. Since this command writes to non-
volatile memory, there will be a delay before an acknowledgment is returned.

Table of Contents

Other manuals for Polycom Vortex EF2211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2211 and is the answer not in the manual?

Polycom Vortex EF2211 Specifications

Power IconPower
input voltage110-240 VAC
frequency47-63 Hz
power consumption25 W
phantom power24 V
Connectors IconConnectors
RS-232DB9F
EF Bus In/OutRJ45
Telephone Line/SetRJ11
Control/StatusDB25F
Audio3.5mm quick connect terminal blocks
Audio Specifications IconAudio Specifications
microphone input-30 dBu to +0 dBu
line inputs-20 dBu to +0 dBu
line outputs-20 dBu to +0 dBu
loudspeaker output10 W, 4-16 Ohms
input impedance10 k Ohms
output impedance50 Ohms
headroom20 dB
signal to noise ratio85 dB
frequency response20 Hz - 22 kHz
Echo and Noise Cancellation IconEcho and Noise Cancellation
total cancellation65 dB
convergence rate40 dB/second
noise cancellation0-15 dB
echo cancellation40 dB, total >65 dB
convergence30 dB/second
cancellation span32 ms
acoustic echo cancellation span270 ms
Operating Environment IconOperating Environment
operating temperature0 °C - 40 °C
status outputs5 V, 20 mA each
Weight and Dimensions IconWeight and Dimensions
width483 mm
length244 mm
height45 mm
weight1.8 kg
shipping weight2.5 kg