Voice Business Group in Atlanta.
Example Description Status Message
S01BROAD2:ATDT4048921180
Sends the string ATDT4048921180 out the RS-
232 port.
S01BROAD2
8.35. BROADA -- Broadcast Commands to Other Connected
Devices
This command is used to broadcast commands to other connected Polycom devices via the EF Bus
and/or ASPI Bus. For example, the command ' S01BROADA:B02PHONE1 ' would cause device ID 1 to
send a command to the EF2241 at device ID 2 to tell it to take its phone off-hook. The EF2241 at
device ID 2 would respond by taking its device off-hook and sending an acknowledgement.
This command is usually used in macros when one needs to have a macro on one device trigger an
action on another device.
Example Description Status Message
S01BROADA:B02PHONE1
Sends the command B02PHONE2
over the digital bus.
S01BROADA
B02PHONE1, this second status
message is from the EF2241 at
device ID 2 when it takes its phone
off hook.
8.36. BUSREF -- Set Which AEC Reference is Placed on EF
Bus
This command sets or queries whic AEC reference (if any) is placed on the EF Bus. Setting BUSREF to
'0' means that no reference is placed on the EF Bus. Setting BUSREF to '1' means that AEC reference
1 (R1) is placed on the bus.
The AEC reference is created in the main matrix via output R1.
Only one Vortex can put a reference on the EF Bus at a time. If more than one Vortex places its
reference on the EF Bus, then an 'ERROR#093' will occur.
This command is an integer command. See
Section 6.2 for more information on this type of
command. The minimum and maximum values for this command are 0 and 2, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.

Table of Contents

Other manuals for Polycom Vortex EF2211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2211 and is the answer not in the manual?

Polycom Vortex EF2211 Specifications

Power IconPower
input voltage110-240 VAC
frequency47-63 Hz
power consumption25 W
phantom power24 V
Connectors IconConnectors
RS-232DB9F
EF Bus In/OutRJ45
Telephone Line/SetRJ11
Control/StatusDB25F
Audio3.5mm quick connect terminal blocks
Audio Specifications IconAudio Specifications
microphone input-30 dBu to +0 dBu
line inputs-20 dBu to +0 dBu
line outputs-20 dBu to +0 dBu
loudspeaker output10 W, 4-16 Ohms
input impedance10 k Ohms
output impedance50 Ohms
headroom20 dB
signal to noise ratio85 dB
frequency response20 Hz - 22 kHz
Echo and Noise Cancellation IconEcho and Noise Cancellation
total cancellation65 dB
convergence rate40 dB/second
noise cancellation0-15 dB
echo cancellation40 dB, total >65 dB
convergence30 dB/second
cancellation span32 ms
acoustic echo cancellation span270 ms
Operating Environment IconOperating Environment
operating temperature0 °C - 40 °C
status outputs5 V, 20 mA each
Weight and Dimensions IconWeight and Dimensions
width483 mm
length244 mm
height45 mm
weight1.8 kg
shipping weight2.5 kg