EasyManua.ls Logo

Polycom Vortex EF2211 - SGGAIN - Set Gain of Signal Generator; SGMUTE - Mute Signal Generator

Polycom Vortex EF2211
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
S01RING1
Enable auto answer mode.
S01RING1
S01RING0
Disable auto answer mode.
S01RING0
S01RING2
Toggle auto answer mode.
S01RINGx , where x is 0 or 1 depending on the current
state of auto answer mode.
S01RING?
Query auto answer mode.
S01RINGx , where x is 0 or 1 depending on the current
state of auto answer mode.
8.141. SGGAIN -- Set Gain of Signal Generator
This command sets the gain of the internal signal generator. The value of SGGAIN specifies the gain
in dB applied to signal generator. A gain of 0 dB produces a signal at nominal level (-20 dB full scale).
This command is an integer command. See
Section 6.2 for more information on this type of
command. The minimum and maximum values for this command are -100 and 20, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01SGGAIN6
Set signal generator gain to 6 dB.
S01SGGAIN6
S01SGGAIN>3
Increase signal generator gain by 3 dB.
S01SGGAINx , where x is the new value of
the signal generator gain. If this command
was issued after the example above, then
the status message would be S01SGGAIN9 .
S01SGGAIN?
Query signal generator gain.
S01SGGAINx , where x is the new value of
the signal generator gain. If this command
was issued after the example above, then
the status message would be S01SGGAIN9 .
8.142. SGMUTE -- Mute Signal Generator
This command controls the muting of the signal generator.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01SGMUTE1
Mute signal generator.
S01SGMUTE1
S01SGMUTE0
Unmute signal generator.
S01SGMUTE0

Table of Contents

Other manuals for Polycom Vortex EF2211

Related product manuals