EasyManuals Logo

Polycom Vortex EF2211 User Manual

Polycom Vortex EF2211
123 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01AGCRATE13
Set AGC ramp rate on input channel
1 to 3 dB/sec.
S01AGCRATE13
S01AGCRATET?
Query the AGC ramp rate on input
channel T .
S01AGCRATETx where x is a number
between 1 and 5, depending on the current
setting of the AGC ramp rate on input
channel T .
8.9. AHCP -- Enable or Disable Call Progress Based Auto
Hangup
This command sets or queries the status of the call progress based auto hangup feature. There are
two methods of auto hangup supported: call progress and loop drop. The call progress method listens
for off-hook or busy tones and hangs up the phone if they are detected. The loop drop method looks
for a drop in loop current on the phone line and hangs up the phone if a loop current drop is detected.
The AHCP command controls the call progress auto hangup feature. The
AHLD command controls the
loop drop auto hangup feature. These two features are controlled and implemented independently.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example Description Status Message
S01AHCP1
Enable call progress based auto hangup mode.
S01AHCP1
S01AHCP0
Disable call progress based auto hangup mode.
S01AHCP0
S01AHCP2
Toggle call progress based auto hangup mode.
S01AHCPx , where x is 0 or 1
depending on the current state of the
call progress based auto hangup mode.
S01AHCP?
Query auto hangup mode.
S01AHCPx , where x is 0 or 1
depending on the current state of the
call progress based auto hangup mode.
8.10. AHLD -- Enable or Disable Loop Drop Based Auto
Hangup
This command sets or queries the status of the loop drop based auto hangup feature. There are two
methods of auto hangup supported: call progress and loop drop. The call progress method listens for

Table of Contents

Other manuals for Polycom Vortex EF2211

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2211 and is the answer not in the manual?

Polycom Vortex EF2211 Specifications

Power IconPower
input voltage110-240 VAC
frequency47-63 Hz
power consumption25 W
phantom power24 V
Connectors IconConnectors
RS-232DB9F
EF Bus In/OutRJ45
Telephone Line/SetRJ11
Control/StatusDB25F
Audio3.5mm quick connect terminal blocks
Audio Specifications IconAudio Specifications
microphone input-30 dBu to +0 dBu
line inputs-20 dBu to +0 dBu
line outputs-20 dBu to +0 dBu
loudspeaker output10 W, 4-16 Ohms
input impedance10 k Ohms
output impedance50 Ohms
headroom20 dB
signal to noise ratio85 dB
frequency response20 Hz - 22 kHz
Echo and Noise Cancellation IconEcho and Noise Cancellation
total cancellation65 dB
convergence rate40 dB/second
noise cancellation0-15 dB
echo cancellation40 dB, total >65 dB
convergence30 dB/second
cancellation span32 ms
acoustic echo cancellation span270 ms
Operating Environment IconOperating Environment
operating temperature0 °C - 40 °C
status outputs5 V, 20 mA each
Weight and Dimensions IconWeight and Dimensions
width483 mm
length244 mm
height45 mm
weight1.8 kg
shipping weight2.5 kg