POWER ELECTRONICS SD450 - DEVICENET
CONFIGURATION OF DEVICENET OPTIONAL BOARD
21
ENGLISH
4.2.3. Assembly Instance Setting (COM-12 Î Out Instance,
COM-13 Î In Instance)
Assembly Instance has 4 types of Sending / Receiving data through
Poll I/O communication. See section ‘7.1.3 Assembly Object’ for
additional information.
4.3. Setting of Other Parameters
4.3.1. Mode Option Setting (COM-02 Î Opt mode)
It allows selecting if Start / Stop command and/or reference
frequency will be given from the network or not. See section ‘8.
Group COM. Parameter List’ to obtain additional information about
the configuration options.
4.3.2. Time Out Setting (I/O-93 Î Setting of time to
determine speed reference signal loss)
When the communication between inverter and DeviceNet network
is disrupted during run, inverter will wait for the time set in this
parameter before considering that reference signal given from the
network has been lost. From this moment on the inverter will stop
according to the setting realized in parameter ‘I/O-92 Î Stop mode
after reference signal loss in communication network’.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Power Electronics SD450 Series and is the answer not in the manual?

Power Electronics SD450 Series Specifications

General IconGeneral
BrandPower Electronics
ModelSD450 Series
CategoryDC Drives
LanguageEnglish

Related product manuals