POWER ELECTRONICS SD450 - DEVICENET
ADDRESS LIST
43
ENGLISH
9.2. Group DRV (Basic Functions and Visualization)
Address Range
16 bit 10 bit
Screen Description
Default
value
Option Values
9100 37120
DRV-00
Cmd. Freq
Reference frequency, output
current (LCD)
0
0 – Max.
freq.
9100 37120
DRV-00
T/K 0.00Hz
R 0.0% F 0.0%
Reference and feedback value 0 0 – 100
9101 37121
DRV-01
Acc. Time
Acceleration time 200 0 – 6000
9102 37122
DRV-02
Dec. Time
Deceleration time 300 0 – 6000
Keypad
Fx/Rx-1
Fx/Rx-2
9103 37123
DRV-03
Drive mode
Start / Stop control mode 1
Int.485
0 – 3
Keypad-1
Keypad-2
V1
V1S
I
V1 + I
Pulse
Int. 485
9104 37124
DRV-04
Freq mode
Frequency control mode
(Method to introduce reference
frequency)
0
Ext. PID
0 – 8
9105 37125
DRV-05
Step Freq-1
Speed at step frequency 1 100
Start freq.
– Max.
freq.
9106 37126
DRV-06
Step Freq-2
Speed at step frequency 2 200
Start freq.
– Max.
freq.
9107 37127
DRV-07
Step Freq-3
Speed at step frequency 3 300
Start freq.
– Max.
freq.
9108 37128
DRV-08
Current
Output current - -
9109 37129
DRV-09
Speed
Motor speed - -