Symptom Cause Remedy Ref.
11. Leakage or insufficient pres-
sure in the low-pressure fuel
system
Leak test (visual inspec-
tion), arrange pressure
check by qualified service
centre
Engine switches itself
off
12. ECM control unit defective
(complete failure)
Arrange inspection by spe-
cialist workshop
13. Voltage supply to the ECM
interrupted or short circuit in
the wiring
Arrange inspection by spe-
cialist workshop
14. Leaks or insufficient pres-
sure in the fuel low pressure
circuit or fuel delivery pump
drive defective
Leak test (visual inspec-
tion); arrange pressure
check by qualified specialist
workshop
Engine is in emergency
operation mode
15. Data flow interruption to the
ECM control unit
Retrieve error log from con-
trol unit, consult professio-
nal service centre
Engine rumbles, rattles
or runs unevenly
16. Malfunction of the fuel sys-
tem
Retrieve error code, consult
professional service centre
Poor engine perform-
ance (low power)
17. Air filter dirty or blocked Replace filter insert
18. Charge air temperature too
high due to dirty charge air
cooler or radiator
Clean charge air cooler and
radiator from the outside
19. Engine coolant temperature
too high
Check temperature sensor,
replace if necessary, check
fan speed; defective ther-
mostat: consult a professio-
nal service centre
20. Fuel system defect (blocked,
leaking)
Check for leaks visually,
consult a professional serv-
ice centre
21. Charge air system leaking,
hose clamp on air inlet hose
loose or defective
Check leaktightness, check
boost pressure sensor, re-
place if necessary, consult
professional service centre
22. The engine diagnosis control
lamp blinks. The AdBlue® /
DEF reserve has been used
up.
Fill AdBlue® / DEF reser-
voir
23. The engine diagnosis control
lamp lights up. Emission-rel-
evant fault or malfunction in
exhaust gas after-treatment
system. Faults or malfunc-
tions can cause damage to
the exhaust gas after-treat-
ment system.
Have the exhaust gas after-
treatment checked in a
qualified service centre
Excessive fuel con-
sumption
24. Connection points (plug-in
pump line and injection jets)
leaking
Leak inspection by qualified
specialist workshop
25. Faulty combustion Have qualified personnel in-
spect the engine