EasyManuals Logo

ProMinent DULCO flex Control Original Operating Instructions

ProMinent DULCO flex Control
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
Index S Name Type Description Objects Attr
Bit 0 = Manual
stop
Bit 1 = Optional
module stop
Bit 2 = Bluetooth
stop
Bit 3 = Init stop
after "Mains power
On"
Bit 4 = Concentra‐
tion mode active
Bit 5 = Diaphragm
rupture sensor
connected
Bit 6 = Bleeding
active
Bit 7 = Cavitation
detected
Bit 8 = Back pres‐
sure too low
Bit 9 - Air in dosing
head
3FBEh 0
PCO_HighestSubIn
dex
U8
1 String Software version
(ASCII)
RO
2 String RO
3 String RO
Tab. 4: 0x5100 – 0x5500
Index S Name Type Description
Max
Objects Attr
5100h 1 Switch-on
counter
U32 Switch-on
counter
SDO RO
5101h 1 Error flags U32 Pump error
flags
SDO RO
5102h 1 Warning flags U32 Pump warn‐
ings
SDO RO
5105h 1 Total revolu‐
tions counter
U32 Total revolu‐
tions counter
SDO RO
5106h 1 Metering
quantity
counter
Float Metering
quantity
counter
SDO RO
5108h 1 Remaining
metering
quantity
Float Remaining
metering
quantity
SDO RO
510Bh 1 Setpoint fre‐
quency
U16 Setpoint fre‐
quency
SDO RW
Supplementary operating instructions for CANopen
11

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals