Index S Name Type Description Objects Attr
Bit 0 = Manual
stop
Bit 1 = Optional
module stop
Bit 2 = Bluetooth
stop
Bit 3 = Init stop
after "Mains power
On"
Bit 4 = Concentra‐
tion mode active
Bit 5 = Diaphragm
rupture sensor
connected
Bit 6 = Bleeding
active
Bit 7 = Cavitation
detected
Bit 8 = Back pres‐
sure too low
Bit 9 - Air in dosing
head
3FBEh 0
PCO_HighestSubIn
dex
U8
1 String Software version
(ASCII)
RO
2 String RO
3 String RO
Tab. 4: 0x5100 – 0x5500
Index S Name Type Description
Max
Objects Attr
5100h 1 Switch-on
counter
U32 Switch-on
counter
SDO RO
5101h 1 Error flags U32 Pump error
flags
SDO RO
5102h 1 Warning flags U32 Pump warn‐
ings
SDO RO
5105h 1 Total revolu‐
tions counter
U32 Total revolu‐
tions counter
SDO RO
5106h 1 Metering
quantity
counter
Float Metering
quantity
counter
SDO RO
5108h 1 Remaining
metering
quantity
Float Remaining
metering
quantity
SDO RO
510Bh 1 Setpoint fre‐
quency
U16 Setpoint fre‐
quency
SDO RW
Supplementary operating instructions for CANopen