4.5.3 DULCO flex Control DFXa, DFXa data objects
Tab. 40: Status and control
Module/
slot
Index Name Module
name
Identifi‐
cation
(hex)
Type Data
flow *
Description
Bit Name Function
1 1 State Status 40.83 u32 R 0 Motor Motor state
0 = Motor idle,
1 = Motor run‐
ning)
1 - -
2 ... 4 Mode 00 – halt
01 – manual
02 – batch
03 – contact
04 – analogue
5 Error There are errors -
see "Errors"
6 Warn‐
ings
There are warn‐
ings - see "Warn‐
ings"
7 Manual
stop
Pump has been
stopped manually
8 Stop Pump has
stopped
9 Priming Pump is in pri‐
ming operation
(higher-level
function)
10 Auxil‐
iary
Pump is in auxil‐
iary operation
(higher-level
function)
11 Pause Pump has been
switched to
‘Pause’
status
(higher-level
function)
12 Module Fieldbus active
13 Tube
Service
Tube Service
being performed
14 Batch
Mem.
Batch memory is
activated
15 Cali‐
brated
Pump is cali‐
brated
16 - -
17 - -
18 - -
Supplementary Operating Instructions for PROFINET
®
66

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals