4.5.3 DULCO flex Control DFXa, DFXa data objects
Tab. 40: Status and control
Module/
slot
Index Name Module
name
Identifi‐
cation
(hex)
Type Data
flow *
Description
Bit Name Function
1 1 State Status 40.83 u32 R 0 Motor Motor state
0 = Motor idle,
1 = Motor run‐
ning)
1 - -
2 ... 4 Mode 00 – halt
01 – manual
02 – batch
03 – contact
04 – analogue
5 Error There are errors -
see "Errors"
6 Warn‐
ings
There are warn‐
ings - see "Warn‐
ings"
7 Manual
stop
Pump has been
stopped manually
8 Stop Pump has
stopped
9 Priming Pump is in pri‐
ming operation
(higher-level
function)
10 Auxil‐
iary
Pump is in auxil‐
iary operation
(higher-level
function)
11 Pause Pump has been
switched to
‘Pause’
status
(higher-level
function)
12 Module Fieldbus active
13 Tube
Service
Tube Service
being performed
14 Batch
Mem.
Batch memory is
activated
15 Cali‐
brated
Pump is cali‐
brated
16 - -
17 - -
18 - -