3
Supplementary operating instructions for PROFIBUS
®
3.1 Requirements............................................................. 46
3.2 Adjusting the pump..................................................... 46
3.2.1 General.................................................................... 46
3.2.2
Switch PROFIBUS
®
to active / inactive...................
46
3.2.3 Setting the slave address........................................ 47
3.3
Special features in active PROFIBUS
®
operation....... 48
3.3.1 General.................................................................... 48
3.3.2 Displays................................................................... 48
3.3.3
LEDs on the PROFIBUS
®
module
........................... 49
3.3.4 Using the metering monitor...................................... 49
3.4 Installation................................................................... 49
3.5 Operation.................................................................... 51
3.5.1 General.................................................................... 51
3.5.2 GSD file................................................................... 51
3.5.3 DULCO flex Control DFXa, DFXa data objects....... 51
3.1 Requirements
Personnel must be familiar with the contents of the "Peristaltic
metering pump DULCO flex Control, DFXa"!
The pump must have the identity code feature "Control type": "R"
PROFIBUS
®
DP interface M 12". The
‘Fieldbus’
menu item is then
available in the operating menu. (When
‘Fieldbus
è
Active’
is set,
‘Settings
è
PROFIBUS’
also appears in the operating menu.)
3.2 Adjusting the pump
3.2.1 General
The pump with PROFIBUS
®
functionality is adjusted in the same
way as the standard pump, with the addition of the bus function‐
ality.
The adjustment process is cancelled in the event
of a pause lasting longer than 60 s.
Using the connected PROFIBUS
®
module, the PROFIBUS
®
pump
represents a device with slave functionality in conformity with DP-
V1. This means that the payload is transferred both cyclically and
acyclically.
3.2.2
Switch PROFIBUS
®
to active / inactive
In order for the pump to be activated using the PROFIBUS
®
,
‘Fieldbus’
must be set to
‘Active’
in the operating menu.
1.
Press the
[Menu]
key to access the
‘Menu’
.
ð
The cursor immediately goes to
‘Information’
.
Supplementary operating instructions for PROFIBUS
®
46

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals