2.10.3 "Production data pump module-specific" register
These register inputs are all only for function code "0x03" (Read
only).
Register Designation Type Display / purpose
200 Version structure definition "Produc‐
tion data" for control module
UINT16 Format: XXXX, consecutive version
number
201 10-digit serial number for control
module
STRING[10] ASCII coding 10 characters
206 Identification tester/test equipment
for control module
STRING[4] ASCII coding 4 characters
208 ICT testing date for control module STRING[10] ASCII coding 10 characters
Date format: DD.MM.YYYY
213 ICT testing time for control module STRING[8] ASCII coding 8 characters
Time format: HH:MM:SS
217 Production order of service provider
for control module
STRING[10] ASCII coding 10 characters
222 Material number of printed circuit
board for control module
STRING[8] ASCII coding 8 characters
226 Revision number of module for con‐
trol module
STRING[2] ASCII coding 2 characters
Hardware version of module
227 Version structure definition "Produc‐
tion data" for power module
UINT16 Format: XXXX,
consecutive version number
228 10-digit serial number for power
module
STRING[10] ASCII coding 10 characters
233 Identification tester/test equipment
for power module
STRING[4] ASCII coding 4 characters
235 ICT testing date for power module STRING[10] ASCII coding 10 characters
Date format: DD.MM.YYYY
240 ICT testing time for power module STRING[8] ASCII coding 8 characters
Time format: HH:MM:SS
244 Production order of service provider
for power module
STRING[10] ASCII coding 10 characters
249 Material number of printed circuit
board for power module
STRING[8] ASCII coding 8 characters
253 Revision number of module for
power module
STRING[2] ASCII coding 2 characters
Hardware version of module
2.10.4 "Production data Modbus module-specific" register
These register inputs are all only for function code "0x03" (Read
only).
Supplementary operating instructions for Modbus RTU
34