2.10.3 "Production data pump module-specific" register
These register inputs are all only for function code "0x03" (Read
only).
Register Designation Type Display / purpose
200 Version structure definition "Produc‐
tion data" for control module
UINT16 Format: XXXX, consecutive version
number
201 10-digit serial number for control
module
STRING[10] ASCII coding 10 characters
206 Identification tester/test equipment
for control module
STRING[4] ASCII coding 4 characters
208 ICT testing date for control module STRING[10] ASCII coding 10 characters
Date format: DD.MM.YYYY
213 ICT testing time for control module STRING[8] ASCII coding 8 characters
Time format: HH:MM:SS
217 Production order of service provider
for control module
STRING[10] ASCII coding 10 characters
222 Material number of printed circuit
board for control module
STRING[8] ASCII coding 8 characters
226 Revision number of module for con‐
trol module
STRING[2] ASCII coding 2 characters
Hardware version of module
227 Version structure definition "Produc‐
tion data" for power module
UINT16 Format: XXXX,
consecutive version number
228 10-digit serial number for power
module
STRING[10] ASCII coding 10 characters
233 Identification tester/test equipment
for power module
STRING[4] ASCII coding 4 characters
235 ICT testing date for power module STRING[10] ASCII coding 10 characters
Date format: DD.MM.YYYY
240 ICT testing time for power module STRING[8] ASCII coding 8 characters
Time format: HH:MM:SS
244 Production order of service provider
for power module
STRING[10] ASCII coding 10 characters
249 Material number of printed circuit
board for power module
STRING[8] ASCII coding 8 characters
253 Revision number of module for
power module
STRING[2] ASCII coding 2 characters
Hardware version of module
2.10.4 "Production data Modbus module-specific" register
These register inputs are all only for function code "0x03" (Read
only).
Supplementary operating instructions for Modbus RTU
34

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals