Parameter
<mode> ECC number operation mode
0 Query ECC numbers
1 Add ECC numbers
2 Delete ECC numbers
<type> ECC number type
0 ECC numbers without (U)SIM
1 ECC numbers with (U)SIM
<eccnum> String type. ECC numbers ( e.g. 110, 119)
Example
AT+QECCNUM=? //Query the supported ECC number operation mode
+QECCNUM: (0-2)
OK
AT+QECCNUM? //Query the ECC numbers with or without (U)SIM
+QECCNUM: 0,"911","112","00","08","110","999","118","119"
+QECCNUM: 1,"911","112"
OK
AT+QECCNUM=0,1 //Query the ECC numbers with (U)SIM
+QECCNUM: 1,"911","112"
num1>[,<eccnum2>,…[,<eccnumN>]]
]
cases, <eccnumN> should be omitted, and the response is:
+QECCNUM: <type>,<eccnum1>,<eccnum2>[]
OK
If <mode> is not equal to 0: <mode>=1 is used to add the
ECC number; <mode>=2 is used to delete the ECC number.
In this case, at least one ECC number <eccnumN> should be
inputted, and the response is:
OK
ERROR
Read Command
AT+QECCNUM?
Response
+QECCNUM: 0,<eccnum1>,<eccnum2>[]
+QECCNUM: 1,<eccnum1>,<eccnum2>[]
OK