LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 94 / 231
1. To prevent the +++ escape sequence from being misinterpreted as data, the following sequence
should be followed:
Do not input any character within 1s before inputting +++.
Input +++ within 1s, and no other characters can be inputted during the time.
Do not input any character within 1s after +++ has been inputted.
Switch to command mode successfully; otherwise return to Step 1.
2. To return back to data mode from command mode, please enter ATO.
3. Another way to change to command mode is through DTR level change, and please refer to AT&D
command for details.
7.7. ATO Switch from Command Mode to Data Mode
The command resumes the connection and switches back from command mode to data mode.
ATO Switch from Command Mode to Data Mode
Response
TA resumes the connection and switches back to data mode
from command mode.
If connection is not successfully resumed:
NO CARRIER
If connection is successfully resumed, TA returns to data
mode from command mode
CONNECT <text>