LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 95 / 231
Parameter
When TA returns to data mode from command mode successfully, CONNECT <text> is returned. Please
note that <text> outputs only when <value> is greater than 0 in ATX<value> parameter setting.
7.8. ATS0 Set Number of Rings before Automatically Answering Call
The command controls automatic answering mode for the incoming calls.
Parameter
If <n> is set too high, the calling party may hang up before the call is answered automatically.
Example
ATS0=3 //Set three rings before automatically answering a call
OK
Read Command
ATS0?
Response
<n>
OK
Write Command
ATS0=<n>
Response
This parameter setting determines the number of rings before
auto-answer.
OK
Maximum Response Time
300ms
Reference
V.25ter
NOTE
NOTE

Table of Contents

Other manuals for Quectel EC25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel EC25 and is the answer not in the manual?

Quectel EC25 Specifications

General IconGeneral
CategoryLTE Module
LTE TDDB38/B40/B41
WCDMAB1/B5/B8
GSM850/900/1800/1900 MHz
Data ratesLTE Cat 4: 150 Mbps DL/50 Mbps UL
GNSSGPS/GLONASS/BeiDou/Galileo/QZSS
Operating Temperature-40°C to +85°C
Form FactorLCC
Storage Temperature-45°C to +90°C
SIM Interface1.8V/3.0V
Antenna InterfaceMain, Diversity, GNSS
LTE FDDB1/B3/B5/B7/B8/B20
InterfacesUSB 2.0, UART, PCM, GPIO
Operating Voltage3.3V - 4.3V
ProtocolsTCP/IP, UDP, FTP, HTTP, HTTPS
CertificationsCE, FCC, PTCRB, GCF, RCM, IC

Related product manuals