LTE Module Series
EC25&EC21 AT Commands Manual
EC25&EC21_AT_Commands_Manual 132 / 231
After the use of Read Command, a delay of 5-10 seconds is required before issuing the Write Command.
Otherwise the +CMS ERROR: 500 may appear.
9.10. AT+CMGW Write Message to Memory
The Write and Execution Commands store short messages from TE to memory storage <mem2>, and
then the memory location <index> of the stored message is returned. Message status will be set to
“stored unsent” by default, but parameter <stat> also allows other status values to be given.
The syntax of input text is the same as the one specified in AT+CMGS Write Command.
Parameter
Test Command
AT+CMGW=?
Response
OK
Write Command
1) If text mode (AT+CMGF=1):
AT+CMGW=<oa/da>[,<tooa/toda>[,<st
at>]]<CR>
text is entered
<Ctrl+Z/ESC>
<ESC> quits without sending
2) If PDU mode (AT+CMGF=0):
AT+CMGW=<length>[,<stat>]<CR>
PDU is given <Ctrl+Z/ESC>
Response
TA transmits SMS message (either SMS-DELIVER or
SMS-SUBMIT) from TE to memory storage <mem2>, and
then the memory location <index> of the stored message is
returned. By default the message status will be set to „stored
unsent‟, but parameter <stat> also allows other status values
to be given.
If writing is successful:
+CMGW: <index>
OK
If there is any error related to ME functionality:
+CMS ERROR: <err>
Maximum Response Time
300ms
Reference
3GPP TS 27.005
NOTE

Table of Contents

Other manuals for Quectel EC25

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel EC25 and is the answer not in the manual?

Quectel EC25 Specifications

General IconGeneral
CategoryLTE Module
LTE TDDB38/B40/B41
WCDMAB1/B5/B8
GSM850/900/1800/1900 MHz
Data ratesLTE Cat 4: 150 Mbps DL/50 Mbps UL
GNSSGPS/GLONASS/BeiDou/Galileo/QZSS
Operating Temperature-40°C to +85°C
Form FactorLCC
Storage Temperature-45°C to +90°C
SIM Interface1.8V/3.0V
Antenna InterfaceMain, Diversity, GNSS
LTE FDDB1/B3/B5/B7/B8/B20
InterfacesUSB 2.0, UART, PCM, GPIO
Operating Voltage3.3V - 4.3V
ProtocolsTCP/IP, UDP, FTP, HTTP, HTTPS
CertificationsCE, FCC, PTCRB, GCF, RCM, IC