Do you have a question about the Radcal ACCU-GOLD2 and is the answer not in the manual?
Model | ACCU-GOLD2 |
---|---|
Category | Measuring Instruments |
Display | LCD |
Type | Dosimeter |
Weight | 300 g |
Accuracy | ±5% or better |
Specifies the minimum hardware and OS requirements for proper software operation.
Provides initial steps to set up hardware and begin making measurements.
Highlights enhancements in the Accu-Gold plus system over legacy models.
Details different digitizer models and their compatible sensor input types.
Details the Accu-Gold Touch system and its sensor configurations.
Explains the various settings available within the device settings menu.
Step-by-step guide on how to perform a measurement using the Accu-Gold system.
Describes how to use the comments pane for notes, copying, and pasting.
Explains the role and installation of license files for sensors.
Instructions for using the AGMS-DM+ sensor and selecting modalities.
Guide on selecting anode/filter combinations for mammographic sensor measurements.
Details on connecting and using multiple sensors simultaneously.
Information on handling and limitations of long exposure measurements.
Guide to calibrating pulsed-fluoroscopy machines and real-time display.
Support for multi-mode exposures like 2D, 3D, and High Contrast.
Describes conditions causing restricted measurements and relevant warnings.
Tips for accurate low dose measurements using ion chambers.
Details on the automatic profile and setting preferred kV result types.
Guide to creating and customizing display profiles for matrix setup.
Instructions for exporting measurement data to Excel from the list view.
How to copy selected cells and delete measurements within the list view.
How to selectively hide or show waveforms in the wave view graph.
Using low-pass bandwidth filters to reduce noise in waveforms.
Steps to create and begin a new measurement session.
Procedure for opening previously saved measurement sessions.
How to import other sessions and save current session progress.
How to use and exit the side-by-side Excel and Accu-Gold view.
Connecting the Accu-Gold digitizer wirelessly using the Nugget adapter.
Accessing waveform data via the Nugget or Touch device.
Detailed steps for installing the Accu-Gold software on a computer.
Procedure for importing necessary calibration files for sensors.
Instructions on how to remove the Accu-Gold software from the system.
General introduction to digitizer function and sensor inputs.
Technical specifications for the 10X6-6 general purpose beam chamber.
Technical specifications for the 10X6-6M dedicated mammography chamber.
Specifications for the 10X6-60 chamber for image intensifier and high dose rate applications.
Specifications for the 10X6-60DAP chamber for DAP measurements.
Specifications for the 10X6-3CT chamber for CTDI and DWP/DLP measurements.
Specifications for the 10X6-10 chamber for R&F and fluoroscopy.
Specifications for the 10X6-180 chamber for leakage and low dose measurements.
Specifications for the 10X6-1800 chamber for low-level radiation measurements.
Specifications for the 10X6-500 chamber for low-level leakage measurements.
Specifications for the 10X6-0.6 chamber for high dose rate applications.
Specifications for the 10X6-0.6CT chamber for CT dose measurements.
Specifications for the 10X6-0.18 chamber for gamma radiation measurements.
Details on the 90M9-AG invasive sensor for mAs measurements.
Details on the 90M10-AG non-invasive sensor for mAs measurements.
Specifications for the discontinued DDX6-W solid-state dose sensor.
Specifications for the DDX6-WL solid-state dose sensor for diagnostic measurements.
Specifications for the AGLS light sensor for illuminance and luminance measurements.
Discussion of enhancements in Accu-Gold+ replacing legacy sensors.
Specifications for the discontinued AGMS-M mammographic multisensor.
Specifications for the AGMS-D multisensor for diagnostic measurements.
Description of the Nugget adapter, its function, and included components.
Explanation of LED indicators for power status and Wi-Fi connectivity.
Steps to wirelessly connect the Nugget to the Accu-Gold 2 software.
Procedure for manually connecting the Nugget via Wi-Fi if automatic connection fails.
Compares measurements and features available across different digitizer modes.
Compares multi-sensor measurement capabilities with digitizer modes.
Comparison of ion chamber measurements across different modes.
Comparison of dose diode measurements across different modes.
Comparison of DAP chamber measurements.
Comparison of mA sensor measurements.
Comparison of light sensor measurements.
Explanation of Radcal's Quiet-Bias technology for improved ion chamber performance.
Details of the soft carrying cases available for Accu-Gold systems.
Details of the hard carrying cases for Accu-Gold systems.
Details of carrying cases specifically designed for the Accu-Gold Touch.
Description of accessories for mammography sensors, like simulated paddles.
Information on the pan-dental positioner for AGMS-D+/DM+ sensors.
Description of the ADTS-W test stand for Accu-Dose.
Description of the AGTS-W test stand for Accu-Gold.
Details the manufacturer's warranty terms for the Accu-Gold system.
Outlines Radcal's policy for repairs outside the warranty period.
Highlights customer responsibility for backing up data before servicing.
States compliance with environmental directives for Accu-Gold products.