Appendix D: Safety around Explosive Devices
D1
Section 21 - Appendix D: Safety around
Explosive Devices
Concerns are expressed from time to time on the hazard of GPR products being used near
blasting caps and unexploded ordnance (UXO). Experience with blasting caps indicates that the
power of Radiodetection’s GPR products is not sufficient to trigger blasting caps. Based on a
conservative independent testing house analysis, we recommend keeping the GPR transmitters
at least 6 feet (2m) from blasting cap leads as a precaution. Some customers do experimental
trials with their particular blasting devices to confirm safety.
We strongly recommend that GPR users routinely working with explosive devices develop a
systematic safety methodology in their work areas.
The UXO issue is more complex and standards on fuses do not exist for obvious reasons. To
date, no problems have been reported with any geophysical instrument used for UXO. Since
proximity and vibration are also critical for UXO, the best advice is to be cautious and
understand the risks.

Table of Contents

Other manuals for Radiodetection RD1500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radiodetection RD1500 and is the answer not in the manual?

Radiodetection RD1500 Specifications

General IconGeneral
BrandRadiodetection
ModelRD1500
CategoryRadar
LanguageEnglish

Related product manuals