1. Set a distance of 205mm [81/8inch] between the upper edge of the entry
frame and the floor using the feet. The distance is required so that the mo-
bile oven rack can move correctly into the unit.
2. Check that the mobile oven rack enters the unit straight. If this is not the
case, use an entry ramp or drive-over aids.
Entry ramp and drive-over aid
n
If the ground is not level, the unevenness must be compensated by an entry
ramp.