5 | Setup
44 / 100 80.06.083_iCombiPro-iCombiClassic_IM_en-US
Observe the distances between the foot locks for the respective unit sizes:
20 half size 20 full size
x [mm] 741 946
x [inch] 29 1/8 37 1/4
a The foot locks and the fixing set are available.
1. Secure the foot locks for the front feet to the floor with the special adhe-
sive or screws and dowels. Make sure that both foot locks point forward
with the openings.
2. Slide the floor unit into the foot locks.
5.3.3 Align mobile oven rack
WARNING
The maximum approach angle of the entry ramp is exceeded
Risk of burns due to hot liquid and food being cooked at too steep an
approach angle.
Make sure that the approach angle of the entry ramp is less than 4 degrees.
NOTE
Malfunction due to inclined mobile oven rack
An incorrectly aligned mobile oven rack can lead to malfunctions in the unit
function, for example during cleaning.
Align the mobile oven rack horizontally in the unit.

Table of Contents

Other manuals for Rational CombiMaster Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus and is the answer not in the manual?

Rational CombiMaster Plus Specifications

General IconGeneral
ModelCombiMaster Plus
ManufacturerRational
CategoryOven
Cooking modesSteam, Convection, Combination
Temperature range30°C to 300°C
Cleaning systemManual cleaning
Power ConsumptionVaries by model
Steam Generator OutputVaries by model
WeightVaries by model
DimensionsVaries by model
Control typeManual
Capacity10-20 levels (depending on model)