EasyManua.ls Logo

Rational CombiMaster Plus

Rational CombiMaster Plus
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | Gas connection for gas units
80.06.083_iCombiPro-iCombiClassic_IM_en-US 83 / 100
2. Use a suitable gas leak detector to check the gas supply and gas distribution
on the unit for leaks.
10.3 Gas consumption by gas type
Natural gas EK G25.3 Netherlands
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Required connection
flow pressure (mbar)
20-30 20-30 20-30 20-30 20-30 20-30
Wobbe index (MJ/
m³) Wi
38.49 38.49 38.49 38.49 38.49 38.49
Wobbe index (MJ/
m³) Ws
42.71 42.71 42.71 42.71 42.71 42.71
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
1.56
m³/h
3.37
m³/h
2.65
m³/h
4.81
m³/h
5.05
m³/h
9.63
m³/h
Max. consumption at
nominal heat load (at
15 °C, 1013 mbar)
13 kW 28 kW 22 kW 40 kW 42 kW 80 kW
Natural gas G20 USA (North America)
6 half
size
6 full
size
10 half
size
10 full
size
20 half
size
20 full
size
Required connection
flow pressure (mbar)
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
6.5-10.
0 in/wc
Wobbe index (MJ/m³)
Wi
45.67 45.67 45.67 45.67 45.67 45.67

Table of Contents