5.5 Notes on the extractor hood
DANGER
Harmful flue gases
Risk of suffocation or poisoning due to concentrations of harmful flue gases
(Carbon monoxide).
n
Make sure that there are sufficient ventilation options in the installation
area.
n
Carry out a flue gas analysis during commissioning of the unit.
n
Install the unit under a kitchen ventilation system.
n
Only for Japan:
The unit must be installed under an exhaust hood.
Local ventilation
Observe the following instructions when installing an exhaust device:
n
VDI Guideline 2052, NFPA96 and the guidelines of the local building com-
mission for extractor hoods.
n
USA and Canada: The exhaust hood must protrude 150-500mm [6–
20inches] over the front of the unit.
n
When using a VarioSmoker, install the unit under an externally ventilated
extractor hood.
n
Install a grease filter in the overhanging area of the extractor hood.