5 | Setup
80.06.083_iCombiPro-iCombiClassic_IM_en-US 47 / 100
If present, use the supplied retaining units (e.g. bracket for wall fixing).
5.5 Notes on the extractor hood
DANGER
Harmful flue gases
Risk of suffocation or poisoning due to concentrations of harmful flue gases
(Carbon monoxide).
n
Make sure that there are sufficient ventilation options in the installation
area.
n
Carry out a flue gas analysis during commissioning of the unit.
n
Install the unit under a kitchen ventilation system.
n
Only for Japan:
The unit must be installed under an exhaust hood.
Local ventilation
Observe the following instructions when installing an exhaust device:
n
VDI Guideline 2052, NFPA96 and the guidelines of the local building com-
mission for extractor hoods.
n
USA and Canada: The exhaust hood must protrude 150-500mm [6–
20inches] over the front of the unit.
n
When using a VarioSmoker, install the unit under an externally ventilated
extractor hood.
n
Install a grease filter in the overhanging area of the extractor hood.

Table of Contents

Other manuals for Rational CombiMaster Plus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational CombiMaster Plus and is the answer not in the manual?

Rational CombiMaster Plus Specifications

General IconGeneral
ModelCombiMaster Plus
ManufacturerRational
CategoryOven
Cooking modesSteam, Convection, Combination
Temperature range30°C to 300°C
Cleaning systemManual cleaning
Power ConsumptionVaries by model
Steam Generator OutputVaries by model
WeightVaries by model
DimensionsVaries by model
Control typeManual
Capacity10-20 levels (depending on model)

Related product manuals