1
Service error: 29
Error tree: Cooling circuit is not working properly, board temperature is over
80 °C
Service error: 29
Unit type: iCombi
V03 · 04/2021 · RTS/Awei · en-EN
Check the maximum temperature of the board in the diagnosis
Maximum temperature over 8C
Check cooling fan
Check, clean or replace air filter
Cooling fan runs when Cooking Mode is selected and the door is closed
No
Display service 29
Cooling circuit is not working properly, board temperature is over 80 °C
YES
YES