Service error: 12
V03 · 05/2021 · RTS/Shof · en-GB
Error tree: CDS sensor not emitting a signal
Service error: 12
Unit type: iCombi
Check the connector on the solenoid valve block and
I/O board, check the CDS sensor signal in the
diagnostic program (pulse counter)
Open the tap, clean the dirt filter in the
water inlet
Is the water pressure on the hand
shower OK?
Yes No
Is the pulse quantity
1360 pulses for iCP
1360 pulses for iCC,
1000 pulses for XS?
Replace the solenoid valve block
Art. 50.02.012 (5x solenoid valve block for iCombi Pro 20 1/1, 20 2/1
Art. 50.02.054 (5x solenoid valve block for iCombi Pro 6 1/1 - 10 2/1
Art. 50.02.102 (3x solenoid valve block + Care for iCombi Classic 6 1/1 - 10 2/1
Art. 50.02.103 (2x solenoid valve block for iCombi Classic 6 1/1 - 10 2/1
Art. 50.02.104 (3x solenoid valve block + Care for iCombi Classic 20 1/1 - 20 2/1
Art. 50.02.105 (2x solenoid valve block for iCombi Classic 20 1/1 - 20 2/1
If an error 42.1 - 4 was also triggered, reset the error via Cleanjet module test.
No

Other manuals for Rational iCombi Classic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational iCombi Classic and is the answer not in the manual?

Rational iCombi Classic Specifications

General IconGeneral
ModeliCombi Classic
MaterialStainless steel
Cooking ModesConvection, Steam
Temperature Range30°C to 300°C
Capacity10, 20
Power Supply400V 3-phase
Power ConsumptionVaries by model
DimensionsVaries by model
WeightVaries by model
Cooking Levels10, 20, or 40

Related product manuals