1
Service error: 42.4
Service error 42.4
Error tree: Care solenoid valve Y4 does not open
Service error: 42.4
Unit type: iCombi
V01 · 05/2021 · RTS/Shof · en-GB
Check that the latest unit software is installed on the
unit.
1
Check the water feed for calcification.
Check the Care solenoid valve Y4 in the function test under service level
(TECLEVEL).
Does the CDS sensor
count up when the Y4 is activated?
Run the iCareSytem.
Once complete, return to the
start screen.
End
Yes
Note on the iCareSystem module test:
Select service level (TECLEVEL) -> "CleanJet &
Care" launcher -> "Module test" tab -> "Module
test iCareSystem".
Replace the solenoid
valve block.
Does water flow into the care
drawer?
Yes
No
Problem solved? EndYes
Remove the side panel of the unit.
No
Check the connectors on the solenoid
valve block and on the I/O board to
ensure that they are connected
correctly to the contacts.
No